UltraSoundGate 416-200 |
part # 34161 #
34162 | |
Ultrasound recording interface with 4 balanced analog inputs, USB 1.1 interface and water-proof transport case.
|
UltraSoundGate 416, front view
|
UltraSoundGate 416, back view
|
|
Number of channels | 4 (4 separate A/D converters) |
ADC type | Delta-Sigma architecture with integrated adaptive anti-aliasing filter |
Resolution | 16 bit (fs<=500kHz) or 8 bit (fs<=750kHz) |
Maximum aggregate sample rate | 500 kHz / 16 bit or 1 MHz / 8 bit |
Sample rates (1 channel / 16 bit) [kHz] | 500, 375, 300, 250, 214, 187.5, 166.6, 150, 125, 100, 75, 62.5, 50 |
Sample rates (2 channels / 16 bit) [kHz] | 250, 214, 187.5, 166.6, 150, 125, 100, 75, 62.5, 50 |
Sample rates (1 channel / 8 bit) [kHz] | 750, 500, 375, 300, 250, 214, 187.5, 166.6, 150, 125, 100, 75, 62.5, 50 |
Sample rates (2 channels / 8 bit) [kHz] | 500, 384, 375, 300, 250, 214, 187.5, 166.6, 150, 125, 100, 75, 62.5, 50 |
Sample rates (3 channels / 8 bit) [kHz] | 300, 250, 214, 187.5, 166.6, 150, 125, 100, 75, 62.5, 50 |
Sample rates (4 channels / 8 bit) [kHz] | 250, 214, 187.5, 166.6, 150, 125, 100, 75, 62.5, 50 |
Frequency response (-3dB, external input without mic) | 20 Hz - 370 kHz |
Acoustic monitor output | no |
Overload indicator (red LED) | yes |
Peak level meter (4 LEDs) | no |
Input sensitivity (max trim) | -43.2dBV = -41 dBu = 6.9 mVrms |
Input sensitivity (min trim) | -3.2dBV = -1 dBu = 0.69 Vrms |
Input sensitivity (max trim) step gain option | -31.8 dBV = -29 dBu = 25.6 mVrms |
Input sensitivity (min trim) step gain option | 2.1 dBV = 4 dBu = 1.28 Vrms |
Gain adjustment potentiometer | 40 dB continuous range (standard) or 33 dB range with 3 dB increments (optional) |
Input impedance | 50 kOhm |
Analog input connectors | female XLR-5 sockets |
Other inputs | external trigger (TTL-compatible), 4 digital inputs (TTL-compatible) |
Computer interface | USB 1.1, isochronous full-speed mode |
Physical USB connection | A-type USB cable fixed to the device |
Maximum power supply current (drawn from the USB) | 450 mA |
Housing | compact aluminum enclosure |
Physical dimensions (W/H/D) in mm | 103 x 56 x 145 |
Weight | 600 g |
|
This compact-sized system is the ideal choice for long-term automatic monitoring in behavioral experiments (e.g. drug testing). In conjunction with the available ultrasound microphones, the Avisoft-RECORDER software and the optional sound analysis software Avisoft-SASLab Pro, this system represents a fully integrated solution for various applications *.
It is a complete out-of-the-box system with no need to struggle with potential interfacing problems between the various components (bat detector, PCI data acquisition board, cables, software, ...). The UltraSoundGate installation procedure is truly plug-and-play.
Other applications include field recording (e.g. bat echolocation/social calls or grasshopper songs) or passive localization of calling animals.
* Until recently, behavioral studies that required long-term ultrasound monitoring commonly used a simple technique that records the presence of ultrasound only. However, this technique has several limitations : narrow frequency range, no detailed information on the structure of the detected calls, preventing in-depth analysis of potentially various call types, difficulties in separating calls from environmental noise.
Listen to a few examples of rat ultrasonic vocalizations recorded with UltraSoundGate.
Principle of the UltraSoundGate 416-200
UltraSoundgate 416-200 User's Guide
Using legacy Avisoft-UltraSoundGate 116 and 416 hardware on Windows Vista, 7, 8 and 10
Recommended accessories for UltraSoundGate 416-200 (part# 34161)
- 4 x condenser ultrasound microphone (part# 40011) or electret ultrasound microphone (part# 40001) with extension cables
- Recording and real-time spectrogram software Avisoft-RECORDER USG, multi-channel, v2.9 for UltraSoundGate 416 (part# 10311)
- Optionally : Sound analysis software Avisoft-SASLab Pro, version 4.40 (part# 10101)
|
|